6 cableado del circuito principal – Yaskawa CIMR-AU Manual del usuario

Página 118

Advertising
background image

Modelo de

variador

Terminal

Calibre recomendado

AWG, kcmil

Rango de cable

AWG, kcmil

Tamaño de

los

tornillos

Torque de ajuste

N·m (lb.in.)

4A0058

R/L1, S/L2, T/L3

4

6 a 4

M8

9 a 11

(79.7 a 97.4)

U/T1, V/T2, W/T3

4

6 a 4

⊖, ⊕1

6 a 1

B1, B2

8 a 4

6

8 a 6

4A0072

R/L1, S/L2, T/L3

3

4 a 3

M8

9 a 11

(79.7 a 97.4)

U/T1, V/T2, W/T3

3

4 a 3

⊖, ⊕1

4 a 1

B1, B2

6 a 3

6

6

4A0088

R/L1, S/L2, T/L3

2

3 a 1/0

M8

9 a 11

(79.7 a 97.4)

U/T1, V/T2, W/T3

2

3 a 1/0

⊖, ⊕1

3 a 1/0

⊕3

6 a 1/0

4

6 a 4

4A0103

R/L1, S/L2, T/L3

1/0

2 a 1/0

M8

9 a 11

(79.7 a 97.4)

U/T1, V/T2, W/T3

1

2 a 1/0

⊖, ⊕1

3 a 1/0

⊕3

4 a 1/0

4

6 a 4

4A0139

R/L1, S/L2, T/L3

3/0

1/0 a 4/0

M10

18 a 23

(159 a 204)

U/T1, V/T2, W/T3

2/0

1/0 a 4/0

⊖, ⊕1

1/0 a 4/0

⊕3

3 a 4/0

4

4

4A0165

R/L1, S/L2, T/L3

4/0

3/0 a 4/0

M10

18 a 23

(159 a 204)

U/T1, V/T2, W/T3

4/0

3/0 a 4/0

⊖, ⊕1

1 a 4/0

⊕3

1/0 a 4/0

4

4 a 2

4A0208

R/L1, S/L2, T/L3

300

2 a 300

M10

18 a 23

(159 a 204)

U/T1, V/T2, W/T3

300

2 a 300

⊖, ⊕1

1 a 250

⊕3

3 a 3/0

4

4 a 300

4A0250

R/L1, S/L2, T/L3

400

1 a 600

M10

18 a 23

(159 a 204)

U/T1, V/T2, W/T3

400

1/0 a 600

⊖, ⊕1

3/0 a 600

⊕3

1 a 325

2

2 a 350

4A0296

R/L1, S/L2, T/L3

500

2/0 a 600

M12

32 a 40

(283 a 354)

U/T1, V/T2, W/T3

500

2/0 a 600

⊖, ⊕1

3/0 a 600

⊕3

1 a 325

M10

18 a 23

(159 a 204)

2

2 a 350

M12

32 a 40

(283 a 354)

4A0362

R/L1, S/L2, T/L3

4/0 × 2P

3/0 a 600

M12

32 a 40

(283 a 354)

U/T1, V/T2, W/T3

4/0 × 2P

3/0 a 600

⊖, ⊕1

4/0 a 600

⊕3

3/0 a 600

M10

18 a 23

(159 a 204)

1

1 a 350

M12

32 a 40

(283 a 354)

3.6 Cableado del circuito principal

118

YASKAWA ELECTRIC TOSP C710616 41E Variador de CA YASKAWA A1000 — Guía de inicio rápido

Advertising