Optional command thc interface, Elec sch:hpr400xd pwr sply w/auto, Hpr pac dry cutting system – Hypertherm HPR400XD Auto Gas Manual del usuario

Página 291: Interface cnc (customer supplied), Optional unit) thc command

Advertising
background image

7-27

Interface

CNC

(Customer Supplied)

HPR PAC

Dry Cutting System

4

3

2

1

1

A

4

3

2

A

B

C

D

B

C

D

141030

CONTROL BOARD

S301

1

2

J300

3

4

3 2 1

4

J303B

J303A

CNC Interface Cable

Workpiece

CNC Interface Cable

(Optional Unit)

THC

Command

CNC Interface Cable

Pendant Ext. Cable

(Optional Unit)

Operator

Pendant

Lifter

Torch

(Optional Unit)

Motor Drive Cable

Lifter I/O Interface Cable

J2B

J2A

PLASMA INTERFACE BD

041842

Serial ID

Dipswitch

Jumper Block

Machine Motion

CNC Interface Cable

Command I/O Cable-Second THC

Command I/O Cable-Third THC

Command I/O Cable-Fourth THC

Notes:

1) For a single system installation set Serial ID (S301),

Machine Motion (J300), J104 & J105 as shown above.

2) For a two system installation duplicate a second power supply and Command THC

as illustrated for a single system, set Serial ID as shown for the second system.

3) For a three system installation set up as described above, set Serial ID as shown

for the third system.

4) For a four system installation set up as described above, set Serial ID as shown

for the fourth system.

5) All machine interface cables (Pwr. supply-CNC) used for serial communication between

Pwr. supply-CNC will have a common connection node with the CNC.

6) The CNC will need a dedicated I/O port for each Command THC.

7) If a Hypertherm Automation controller is being used, and there are intermittent communication

failures (PS Link Failure), try removing the jumpers on J104 and J105 on the control board,

and the termination jumper (J6 or J8) on the serial isolation board in the controler.

Only remove the termination jumper on the serial isolation board that is connected

to the HPR power supply. See figure on Sheet 19 for details.

Dipswitch

Serial ID

S301

S301

Dipswitch

Serial ID

S301

Dipswitch

Serial ID

1 2

J104

1 2

J105

Optional Command THC Interface

See Command

THC Manual for

internal Power

Supply wiring

Torch

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

for second system

for third system

for fourth system

ELEC SCH:HPR400XD PWR SPLY W/AUTO

E

013374

SHEET 23 OF 24

S301

1 2 3 4 5 6 7 8

All switches are in the OFF position

Dipswitch setting example: As shipped

2

1

3 4

5 6

7 8

ON

ON

Advertising