Installing/mounting

5.5 Mounting with mounting brackets

SIMATIC IPC427C
Operating Instructions, 04/2009, A5E02414743-01

31

Mounting/demounting the device

The dimensions of the device with mounting brackets are listed under Dimension drawings of

the device with mounting brackets (Page 99).

Mounting examples
Material

Bore diameter

Mounting

Concrete

8 mm diameter

60 mm depth

Dowel: 8 mm diameter

50 mm length

Screws: 4 mm diameter

50 mm length

Plasterboard

(min. 13 mm thick)

14 mm diameter

Gravity toggle: 4 mm diameter

50 mm length

Metal

(min. 2 mm thick)

5 mm diameter

Metal screws M 4: 4 mm diameter

15 mm length

WARNING

Ensure that the wall or ceiling can hold four times the total weight of the device (including

the cabinet brackets and additional expansion modules).