Siemens Simatic Industrial PC IPC427C User Manual

Page 14

Advertising
background image

Description

3.3 Features

SIMATIC IPC427C

14

Operating Instructions, 04/2009, A5E02414743-01

Basic data
Ports
Serial

COM1 (RS232)
COM2 (RS232); optional

Graphics

DVI-I: combined DVI and VGA

USB

4 x USB 2.0 high current

Ethernet

2 x RJ 45 (10/100/1000 Mbps)

PROFIBUS DP

12 Mbps (isolated potential,

compatible to CP 5611), optional

CAN interface

Optional

Keyboard, mouse

Connected via external USB port

Monitoring and safety functions
Temperature

When permitted temperature range is exceeded

Warnings can be analyzed by application program

(local, via LAN)

Watchdog

Monitoring function for program execution

Restart can be parameterized in the event of a fault

Warnings can be analyzed by application program

(local, via LAN)

LED display

4 LEDs for displaying system status

2 of these can be programmed by the user

1

Transient voltage interruption

Up to 15 ms buffer time at full load

Buffer memory

2 MB battery-buffered SRAM

1

Software
Operating systems
Available

Without

Windows Embedded Standard 2009

Windows XP Professional MUI SP3 preinstalled

2

Project-specific

LINUX

QNX

VxWorks

Others on request

RMOS3 V3.40 (ordered separately)

1

You can find additional information about addressing the LEDs or the SRAM under a

Windows operating system in the section "Output register LED L1/L2". You can find example

programs for addressing the LEDs under Windows XP and under RMOS3 under the FAQ at

the Customer Support site Industry Automation and Drive Technologies - Homepage

(

http://www.siemens.com/automation/service&support

).

2

MUI: Multi Language User Interface; 5 languages (English, German, French, Spanish,

Italian)

Advertising