6 mapa del menú del me-ags-n utilizando el me-arc, 0 utilización de un módulo ags, El menú – Magnum Energy ME-ARC Remote Manual del usuario

Página 97: Setup continua en la página siguiente

Advertising
background image

©2012 Magnum Energy, Inc.

91

7.0 Utilización de un Módulo AGS

SETUP

S

Set Stop Gen

Volts= 9.1

Estado...

04 AGS Setup

04B Gen Run Time

OFF

04A Gen Run VDC

11.5 to 14.4

Set Stop Gen

AM-PM =

00:00

A

Set Stop Gen

Minute =

00:

00

P

Set Gen Run Time

OFF

Set Start Gen

AM-PM =

00:00

A

Set Stop Gen

Hour = 1

:00 P

Set Start Gen

Hour = 1

:00 A

Set Start Gen

Minute =

00:

00

A

METER

Estado...

03 AGS Meters

03A AGS Status

Status...

03B DC Volts-AGS

0.0 VDC

03C Gen Run Time

0.0 Hours

03D AGS Temp

00F

03E Since GenRun

00 Days

Pantalla de solo lectura

Set Start Gen

Volts= OFF

Set Start Volts

Delay = 0 Sec

Set Stop Volts

Delay = 0 Sec

Set Start Gen

Volts= 11.5

Set Start Gen

Volts= 16.0

...

Set Start Volts

Delay = 120 Sec

Set Start Volts

Delay = 127 Min

...

Set Stop Gen

Volts= 14.4

S

S

S

S

Set Stop Volts

Delay = 120 Sec

Set Stop Volts

Delay = 127 Min

...

Set Gen Run Time

ON

S

Set Start Gen

Hour = 12

:00 A

...

Set Start Gen

Minute =

00:

59

A

...

Set Start Gen

AM-PM =

00:00

P

S

S

Set Stop Gen

Hour = 12

:00 P

Set Stop Gen

Minute =

00:

59

P

Set Stop Gen

AM-PM =

00:00

P

...

...

S

S

S

S

El menú

SETUP continua en la página siguiente

S

Set Stop Gen

Volts= Float

...

CTRL

03 Gen Control

OFF

Set Gen Control

OFF

Set Gen Control

ON

S

Set Gen Control

AUTO

...

...

...

...

AC In

Ready

Start Topoff

Fault Temp

Gen Cooldown

Start Amp

Start VDC

Fault Test

Gen Warm-up

Start Exercise

Gen Run Fault

Fault Time

Manual Run

Start SOC

Fault Amp

Fault Topoff

No Comm

Start Temp

Fault Exercise

Fault VDC

Off

Start Test

Fault MaxRn

Quiet Time

Start Time

Fault SOC

Estados disponibles:

Rangos de voltaje de inicio del generador:

12v = 9,0 a 15,9 VCC; 24v = 18,0 a 32,0 VCC;

48v = 36,0 a 64,0 VCC

Rangos de voltaje de parada del generador:

12v = 9,1 a 16,0 VCC; 24v = 18,2 a 32,0 VCC;

48v = 36,4 a 64,0 VCC

Predeterminado: OFF

7.6

Mapa Del Menú del ME-AGS-N Utilizando el ME-ARC

Ilustración 7-2, Mapas de Menú ME-AGS-N Utilizando el Control

Remoto ARC (Sección 1)