3 controlador y tableros de extension 1-16, 3 controlador y tableros de extensión 1-16 – DoorKing Remote Account Manager Manual del usuario

Página 24

Advertising
background image

2.3.3

Controlador Y Tableros De Extensión 1-16

Main

Term

in

al

1833

, 1

8

3

5

, 183

7

, 1838

CONTROLLE

R

N

O

TES:

C

ont

rol

ler

main

t

e

rm

inal

s

15

-16-

1

7

=

S

YST

E

M

RE

LA

Y 1

.

C

ont

rol

ler

main

t

e

rm

inal

s

13

-14

=

SY

STEM

RE

LA

Y

2.

R

e

lay

0

i

s

not

av

ai

la

ble

on

t

he 1

838

c

ont

roll

er.

A

u

xilia

ry T

e

rm

inals

14
13
12
11

10

9
8
7

6
5

4
3

2
1

NEG 12 VDC BATT INPUT
POS 12 VDC BATT INPUT

+ 12 VDC

COMMON

DATA 1
DATA 0

Elevator

Control

RS 232
Connection

1
2
3
4
5
6

1
2
3

1 2 3

17

16

15

14

13

20

19

4

6

18

30 Series Controller to 2351-010 Expansion Boards 1-16
Detail Wiring

C.O.
PHN

16 VAC

PWR

INPUT

16 VAC

PWR

INPUT

5
6

7
8
9

12
13
14

6
7
8
9

10

17

GRN
WHT

BLK

RED

BLU

RED

BRN

WHT
GRN

BLK

16 VAC

PWR

INPUT

BLU

BR

N

To

Boards

3-8

DOORKING, INC., INGLEWOOD, CA 90301

Date:

Dwg. No.

Detail Wiring - 30 Series Controller to 2351-010
Expansion Boards 1-8

Rev.

Title:

3/03

A

M1835-065-4

To Main
Door / Gate

Central Office phone line - touch tone, loop start.

2

A switch closure across terminals 4 & 6 will activate relay 1
for its programmed strike time.

Battery Backup - separate batteries required for phone
system and weigand terminals.

3

16 Volt, 20 VA UL Listed Transformer.

4

1

2

4

4

4

4

Belden 9931 or Equivalent. Shield runs continuous. Float the shield, do not
connect shield to 2351-010 board common.

Belden 9418 or Equivalent. If reader is lighted, Belden 9931 can be used to
provide extra wires for light power.

Communication cable to additional boards is connected in parallel. Allows “teeing” of
communication cable for optimal cable routing.

For 1837, use 16 Volt, 40 VA UL Listed Transformer.

Power for door strikes or magnetic locks is not provided by the system. It must be
provided by an external power supply.

Aux power transformer must be connected. Otherwise, RS232, elevator control and
weigand inputs will not function.

No connection at controller.

12

9

10

11

5

6

7

8

See Dwg No. M1835-065-5 for
detail.

5

7

CARD

RDR

CARD

RDR

11

RED

9

10

10

8

12

16 VAC
OUTPUT

1

LOCK

PWR

DOOR

LOCK

+

+

3

3

13

EARTH Ground.

13

13

13

P2

P1

2351-010

5
6

7
8
9

12
13
14

6
7
8
9

10

17

GRN
WHT

BLK

RED

BLU

RED

BRN

WHT
GRN

BLK

16 VAC

PWR

INPUT

DOOR

LOCK

LOCK

PWR

P2

P1

2351-010

5
6

7
8
9

12
13
14

6
7
8
9

10

17

GRN
WHT

BLK

RED

BLU

RED

BRN

WHT
GRN

BLK

16 VAC

PWR

INPUT

DOOR

LOCK

LOCK

PWR

P2

P1

2351-010

5
6

7
8
9

12
13
14

6
7
8
9

10

17

GRN
WHT

BLK

RED

BLU

RED

BRN

WHT
GRN

BLK

16 VAC

PWR

INPUT

DOOR

LOCK

LOCK

PWR

P2

P1

2351-010

Relay 0

NO

NC

CO

M

CARD

RDR

CARD

RDR

BLK
WHT
GRN

BLK
WHT
GRN

+ 12 VDC

COMMON

DATA 1
DATA 0

BL

U

BR

N

6

6

7

7

7

10

10

13

13

4

4

9

To

Boards

9-16

24

Advertising
Este manual se refiere a los siguientes productos: