Valores de par de los pernos – Goulds Pumps IC - IOM Manual del usuario
Página 80
Energía
nominal P
N
en kW
Bomba
Bomba y motor
2.950 min
-1
1.450 min
-1
975 min
-1
2.950 min
-1
1.450 min
-1
975 min
-1
1.5
55.5
55.0
54.5
63.5
57.0
56.0
2.2
58.0
57.0
56.5
64.5
59.0
58.5
3.0
59.5
58.5
58.0
68.5
61.0
62.0
4.0
61.0
60.0
59.5
69.0
63.0
63.0
5.5
63.0
62.0
61.5
70.0
65.0
65.0
7.5
64.5
63.5
63.0
70.5
67.0
67.0
11.0
66.5
65.5
65.0
72.0
69.0
68.5
15.0
68.0
67.0
66.5
72.5
70.0
70.5
18.5
69.0
68.5
68.0
73.0
70.5
74.0
22.0
70.5
69.5
69.0
74.5
71.0
74.0
30.0
72.0
71.0
70.5
75.0
72.0
73.0
37.0
73.0
72.0
71.5
76.0
73.5
73.5
45.0
74.0
73.0
72.5
77.0
74.5
73.5
55.0
75.5
74.5
74.0
78.0
75.5
75.0
75.0
77.0
76.0
75.5
80.0
76.5
76.0
90.0
78.0
77.0
—
80.5
77.5
—
110.0
79.0
78.0
—
82.5
78.5
—
132.0
80.0
79.0
—
83.0
79.5
—
160.0
81.0
80.0
—
83.5
80.5
—
Notas de tabla:
• Nivel de presión acústica L
pA
medido a 1 m de distancia de la superficie de la bomba según DIN
45635, parte 1 y 24.
• No se consideran las influencias de cimentación y del lugar.
• La tolerancia para estos valores es +/-3 dB(A).
• Suma con operación de 60 Hz:
• Bomba: —
• Bomba con motor: +4 dB (A)
Valores de par de los pernos
Valores de par de los tornillos
En esta tabla se proporcionan los valores de par recomendados de los tornillos.
Posición
Tamaño de los pernos
Par para las roscas
lubricadas en libras/
pies (Nm)
Par para las roscas
secas en libras/pies
(Nm)
Tornillos de la carcasa
M12
26 (35)
37 (50)
M16
77 (105)
111 (150)
M20
155 (210)
225 (305)
Todos los demás tornillos
M10
30 (40)
37 (50)
M12
44 (60)
66 (90)
M16
111 (150)
162 (220)
Valores de par de las tuercas
En esta tabla se proporcionan los valores de par recomendados de las tuercas.
Mantenimiento
78