esTrUcTUra De Menú HarT DeL eQUipo ecLipse
Esta sección muestra los diagramas de menús para el equipo Pointwatch Eclipse. El diagrama de menús permite

apreciar los principales comandos y opciones disponibles cuando se utilizan selecciones del menú.

1 Device Setup
2 Gas xxxxxxx
3 PV xxx %LEL
4 PV AO xxx mA
5 PV URV xxx % LEL

1 Process Variables

2 Diag/Service

3 Basic Setup

4 Detailed Setup

5 Review

1 Reference xxxx

2 Snsr Temp xxxx

3 Operating Mode

4 Calibration

5 xmtr flt 1

6 xmtr flt 2

7 xmtr status 1

8 xmtr status 2

1 Zero Trim

2 Calibrate Sensor

3 Cal Date 12/2/2000

4 D/A Trim

1 4 mA

2 20 mA

3 Other

4 End

1 Self Test

2 Response Test

3 Reset

1 Gas xxxxxxxx

2 Conc 0.0% LEL

3 AO 4.00 mA

1 Running hrs xxxx

2 Max Temperatures

3 Min Temperatures

4 Cal Log

5 Event Log

% LEL

ppm

Vol %

1 URV 20-100% LEL

2 LRV 0% LEL

3 USL 100% LEL

4 LSL 0% LEL

1 Tag xxxxxx

2 Date: 6/30/2000

3 Descriptor

4 Message

5 Model: Eclipse

6 Write Protect xx

7 Revision #'s

8 Final Assembly #

9 Dev id xxxxxx

1 PV USL xxxx unit

2 Active xxxx

3 Reference xxxx

4 Ratio xxxx

5 Absorption xxxx%

6 Span Factor xxxxx

7 Snsr Temp xx degC

8 Vol % @ 100% LEL

9 Coefficient A

Coefficient B

Coefficient C

Coefficient D

Coefficient E

Spcl

Methane

Ethane

Propane

Ethylene

Propylene

Butane

Spare 6

Spare 7

Spare 8

1 Config Gas Alarms

2 Config Fault Out

3 Hart Output

4 Com Port

1 Password

2 Set Write Protect

3 Write Protect xx

Disable

Enable

Change Password

1 Protocol xxxxx

2 Poll Addr xxx

3 Baud Rate xxxx

4 Parity xxxx

1 EQ DIP Switch xxx

1 Poll Addr xx

2 Num Req preams x

1 Analog Fault Codes

2 Analog Code Values

1 High Alarm Level

2 High Alarm Latch

3 Low Alarm Level

4 Low Alarm Latch

Spcl Gas Coef A

Spcl Gas Coef B

Spcl Gas Coef C

Spcl Gas Coef D

Spcl Gas Coef E

Spcl Gas Vol %

1 Universal Rev 5

2 Fld Dev Rev 1

3 Software Rev xxx

Running Hrs xxxxx

Event History

(Event)

xxxxx Hrs

1 Previous

2 Next

3 Exit

Running Hrs xxxxx

Calibration History

(Event)

xxxxx Hrs

1 Previous

2 Next

3 Exit

Running Hrs xxxxx

Minimum Temperature

xxxx Deg C xxxx Hours

Min Temp Since Reset

xxxx Deg C xxxx Hours

Reset Min & Max Temp?

ABORT OK

Running Hrs xxxxx

Maximum Temperature

xxxx Deg C xxxx Hours

Max Temp Since Reset

xxxx Deg C xxxx Hours

Reset Min & Max Temp?

ABORT OK

1 Calibrate

2 Cal Conc xxxx

3 Cal Gas xxxx

4 Gas Type xxxx

5 Calib Type xxxx

6 Cuvette Length

Same

Methane

Propane

Std

Cuvette

Eclipse

PIR 9400

User Defined

1 Warm Up

2 Blocked Optics

3 Calibration

4 Fault

Modbus

ASCII

1200

2400

4800

9600

19.2K

None

Even

Odd

1 Test Device

2 Loop Test

3 Calibration

4 Status

5 History

1 Tag xxxxxx

2 PV Unit xxxxxx

3 Range Values

4 Device Information

5 Gas xxxxxxxx

1 Sensor Information

2 Gas Type xxxxx

3 Output Condition

4 Device Information

5 Write Protect

NOTA

Consulte “Relés de alarma” en
la sección Especificaciones
de este manual para obtener
información importante respecto
de los relés de alarma.