background image

Cache Board Present: True

Cache Status: OK

Accelerator Ratio: 10% Read / 90% Write

Drive Write Cache: Disabled

Total Cache Size: 1024 MB

Total Cache Memory Available: 816 MB

No-Battery Write Cache: Disabled

Cache Backup Power Source: Capacitors

Battery/Capacitor Count: 1

Battery/Capacitor Status: OK

SATA NCQ Supported: True

Spare Activation Mode: Activate on drive failure

Controller Temperature (C): 40

Cache Module Temperature (C): 0

Capacitor Temperature (C): 0

Boot Controller: True

Primary Boot Volume: logicaldrive 1

Secondary Boot Volume: logicaldrive 1

Ejemplo 2:

=> ctrl all show

Puesto que este destino está formado por diferentes dispositivos, la salida será corta. Una salida
típica sería:

MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn:
500805F3000BAC11)

Smart Array 5312 in Slot 3 (sn: P4AB5X9BFMLNTJ)

Smart Array 532 in Slot 2 (sn: P44940LDAORS4F)

Ejemplo 3:

=> ctrl ch="lab4" show config

En este caso, la salida contendrá información detallada, puesto que el destino consiste únicamente
de un dispositivo. Una salida típica sería:

MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn:
500805F3000BAC11)

array A (SAS, Unused Space: 20091 MB)

logicaldrive 1 (219 MB, RAID 6(ADG), OK)

physicaldrive 1:1:3 (port 1:box 1:bay 3, SAS, 4.3 GB, OK)

physicaldrive 1:1:4 (port 1:box 1:bay 4, SAS, 9.1 GB, OK)

ESES