4 installation – Dometic MCS15 User Manual

Page 26

Advertising
background image

EN

Installation

MCS5, MCS15

26

Seawater Intake (Detail A)

8.9.4

Installation

➤ Install the seawater speed scoop intake as far below the water line

and as close to the keel as possible and with intake facing the bow.
This keeps the intake in the water when the boat heels over so that
air does not get into the system.

➤ Bed the scoop with a marine sealant designed for underwater use.
➤ Apply the bedding compound liberally to both sides and the through-

out hole.

➤ Install a bronze, full flow seacock on the speed scoop thru-hull inlet.
➤ Install a seawater strainer below the level of the pump with access to

filter.

➤ Connect the seacock and strainer with an uphill run of 5/8

"

(16 mm)

reinforced marine grade hose.

➤ Mount the seawater pump securely above the strainer, at least

300 mm below the water line.

➤ Rotate pump head toward the direction of water flow.
➤ Mount the air conditioning unit by securing the base pan onto a flat,

horizontal surface with the mounting clip brackets and the 4 screws.
The base pan also serves as a condensate pan.

➤ Connect the discharge from the pump uphill to the bottom inlet of the

air conditioning unit’s condenser coil with 5/8

"

(16 mm) reinforced

marine grade hose.

➤ Install the overboard discharge thru-hull fitting.
➤ Connect the discharge from the condenser coil to the overboard

discharge thru-hull fitting with 5/8

"

(16 mm) reinforced marine grade

hose.

Item in A

Description

12

Seawater house

13

Hose clamps

14

PVC adapter, 1/2" MPT x 1/2" HB

15

Ball valve

16

Nut

17

Backing plate (not included in kit)

18

Bedding compound (not included in kit)

19

Hull

20

Speed scoop