Dometic MCS15 User Manual

Page 22

Advertising
background image

EN

Installation

MCS5, MCS15

22

8.8

Control Panel Installation

The following guidelines should be followed during the installation of the
control panel:

Mount the control panel within 4.5 m of the electrical box.

Mount the control panel on an inside wall, slightly higher than mid-
height of the cabin, in a location with freely circulating air where it can
best sense average temperature.

Do not mount the control panel
– in direct sunlight,
– near any heat producing appliances
– in a bulkhead where temperatures radiating from behind the panel

may affect performance

– in the supply-air stream
– above or below a supply or return-air grille

Before mounting the control panel, consider the location:

➤ Create a cut out size for the control panel:

64 mm wide by 48 mm high.

➤ Plug one end of the display cable (8-pin RJ-45 connector) into the

display socket (J-2) of the electric box and the other end into the back
of the control panel.

➤ Prior to placement clean the mounting surface with isopropyl alcohol

only (test alcohol on hidden portion of surface first).

➤ Secure the control panel to a bulkhead with the adhesive strips pro-

vided.

8.9

Unit and Seawater System Installation

8.9.1

Guidelines for Seawater System Installation

A

NOTICE!
If the sea water screen filter is not installed, the pump can be damaged
and the warranty for the pump will be invalidated.

I

NOTE
If the sea water screen filter is not installed, the warranty for the pump will
be invalidated.

The following guidelines should be followed during the installation of the
seawater system:

Advertising