4 electrical box – Dometic MCS15 User Manual

Page 19

Advertising
background image

EN

19

MCS5, MCS15

Installation

8.3.2

MCS15

The auxiliary vertical-support bracket must be used when the blower is
vertical or unit damage will occur, voiding the warranty.

➤ Remove and discard the 2 self-tapping screws that attach the blower

to the drain pan.

➤ Remove wire tie holding blower wire harness to base pan and/or

adjacent harness.

➤ Remove and save the 7 screws (fig. 4 5, page 4) holding the blower

plate to the evaporator shroud.

➤ Rotate the blower 90° so the discharge is in the vertical position and

aimed upward.

➤ Reinstall the 7 screws to hold the blower plate to the evaporator

shroud.

➤ Locate the auxilliary vertical support bracket (fig. 4 3A and 3B,

page 4) attached to the pan.

➤ Remove and save the 2 screws (fig. 4 2, page 4) in the end A

(fig. 4 3A, page 4).

➤ Remove and save the 2 self-tapping screws (fig. 4 4, page 4) that at-

tach blower to drain pan.

➤ Using the 2 screws you just removed from the end A, mount the end A

to the inside of the pan (fig. 4 6, page 4).

I

NOTE
Self-tapping screws will drill their own pilot holes if a screw gun is used,
but if pilot holes are necessary, utilize a 0.5 mm drill bit with a drill stop or
other method to block the drill bit from going deeper than 6 mm into the
blower housing, as the fan blade will be damaged.

➤ Using 2 of the self-tapping screws you just removed, mount the end B

(fig. 4 3B, page 4) of the bracket to the blower housing (fig. 4 7,
page 4).

➤ Make sure the power wire is repositioned so it will not catch on any-

thing during or after installation.

✓ The vertical rotation is complete.

8.4

Electrical Box

The following guidelines should be followed during the installation of the
electrical box:

Mount the electrical box in a dry location.

Mount the electrical box to a solid surface within 1 m of the unit.

Advertising