Technical characteristics
1) This appliance conforms with EEC

Circular 82/499 on limitation of radio-
electric disturbance. The parts of this
appliance coming into contact with
foodstuffs comply with Decree Law 108
of 25/01/92 (EEC Directive 89/109).

2) Dimensions:

Height:

365 mm

Width:

410 mm

Depth:

395 mm

3) Volume:

59 L

Installation
ATTENTION: This appliance must only
be installed and operate in permanently
ventilated areas as per UNI 7129 and
UNI 7131.
IMPORTANT: Installation must be
performed following the manufacturer’s
instructions by professionally qualified
personnel. Any maintenance work must
be performed with the appliance
disconnected from the electrical power
supply and the gas tap turned off.
Installation must be performed in
compliance with current regulations,
particularly:

UNI 7129 on mains gas installation for

domestic use

UNI 7131 on liquid propane gas

installation for domestic use

Relevant CEI electrical regulations.

Electrical mains connection:
check that the voltage corresponds with
the one indicated on the technical data
plaque on the lower surface of the frame.
If the plug is not easily accessible, the
installer must install a multi-pole switch
with a contact opening distance of at least
3 mm.
The equipment is supplied with a cable
with no plug. A standard type plug must
be used, remembering that:

- green-yellow wire

= earth

- blue wire

= neutral

- brown wire

= live.