A especificaciones técnicas, Ftb-720, Mportante – EXFO iOLM Manual del usuario
Página 171: Asignador de tramos óptico inteligente, Technical specifications, General specifications

Asignador de tramos óptico inteligente
165
A Especificaciones técnicas
FTB-720
I
MPORTANTE
Las siguientes especificaciones técnicas pueden cambiar sin previo
aviso. La información contenida en esta sección se proporciona
únicamente como referencia. Si desea obtener las especificaciones
técnicas más recientes del producto, visite la página web de EXFO
en www.exfo.com.
TECHNICAL SPECIFICATIONS
Wavelength (nm)
b
850 ± 20, 1300 ± 20, 1310 ± 20, 1550 ± 20, 1625 ± 15 (filtered)
Dynamic range
(dB)
c, d
27, 26, 36, 34, 34
Event dead zone (m)
e
0.8
Attenuation dead zone (m)
e
4, 4.5, 5, 5, 5
Distance range (km)
Multimode: 0.1, 0.3, 0.5, 1.3, 2.5, 5, 10, 20, 40
Singlemode: 1.25, 2.5, 5, 10, 20, 40, 80, 160, 260
Pulse width (ns)
Multimode: 5, 10, 30, 50, 100, 275, 500, 1000
Singlemode: 5, 10, 30, 50, 100, 275, 500, 1000, 2500, 10 000, 20 000
Launch conditions
f
Class CPR 1 or 2
i
Linearity (dB/dB)
b
±0.03
Loss threshold (dB)
0.01
Loss resolution (dB)
0.001
Sampling resolution (m)
Multimode: 0.04 to 2.5
Singlemode: 0.04 to 5
Sampling points
Up to 256 000
Distance uncertainty (m)
g
±(0.75 + 0.0025 % x distance + sampling resolution)
Measurement time
User-defined (60 min. maximum)
Typical real-time refresh (Hz)
3
Stable source output power (dBm)
h
–3 (1300 nm), –7 (1550 nm)
GENERAL SPECIFICATIONS
Size (H x W x D)
130 mm x 36 mm x 252 mm (5
1
/
8
in x 1
7
/
16
in x 9
15
/
16
in)
Weight
0.65 kg (1.4 lb)
Temperature
Operating
Storage
0 °C to 50 °C (32 °F to 122 °F)
–40 °C to 70 °C (–40 °F to 158 °F)
Relative humidity
0% to 95% non-condensing
NOTES
a.
All specifications valid at 23 °C ± 2 °C with an FC/PC connector, unless otherwise specified;
APC connector for FTB-720 singlemode model.
b. Typical.
c. Typical dynamic range with longest pulse and three-minute averaging at SNR = 1.
d.
Multimode dynamic range is specified for 62.5 μm fiber; a 3 dB reduction is seen when testing
50 μm fiber.
e.
Typical dead zone for multimode reflectance below –35 dB and singlemode reflectance below
–45 dB, using a 5 ns pulse.
f. For multimode port, controlled launch conditions allow 50 μm and 62.5 μm multimode fiber testing.
g. Does not include uncertainty due to fiber index.
h.
Typical output power is given at 1300 nm for multimode output and 1550 nm for singlemode output.
i. Under improvement to achieve better conditions.