COPPER SPECIFICATIONS
a, b, c
Transmitter characteristics
Frequency range (200 Hz to 20 kHz)
Frequency resolution
1 Hz steps
Frequency uncertainty (accuracy)
±(50 ppm + 1 Hz)
Level range
–20 dBm to 0 dBm at 600
1
Level resolution
0.1 dB
Level uncertainty (accuracy)
±1 dB
Frequency range (20 kHz to 2.2 MHz)
Frequency resolution
1 kHz steps
Frequency uncertainty (accuracy)
±(50 ppm + 100 Hz)
Level range
–20 dBm to 0 dBm at 100
1
Level resolution
0.1 dB
Level uncertainty (accuracy)
±1 dB
Frequency range (2.2 MHz to 17 MHz)
Frequency resolution
1 kHz steps
Frequency uncertainty (accuracy)
±(50 ppm + 100 Hz)
Level range
–20 dBm to 0 dBm at 100
1
Level resolution
0.1 dB
Level uncertainty (accuracy)
±1 dB
Frequency range (17 MHz to 30 MHz)
Frequency resolution
1 kHz steps
Frequency uncertainty (accuracy)
±(50 ppm + 100 Hz)
Level range
–20 dBm to 0 dBm at 100
1
Level resolution
0.1 dB
Level uncertainty (accuracy)
±1 dB
Impedance
100
1, 120 1, 135 1, 150 1, 600 1
Receiver characteristics
Reception frequency range
200 Hz to 20 kHz
20 kHz to 30 MHz
Frequency uncertainty (accuracy)
±(50 ppm + 1 digit)
VF reception level range
–90 dBm to 15 dBm at 600
1
VF level uncertainty (accuracy)
200 Hz to 20 kHz
–90 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB
WB reception level range
–80 dBm to 15 dBm at 100
1, 120 1,135 1, 150 1
WB level uncertainty (accuracy)
20 kHz to 2.2 MHz
–80 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB
2.2 MHz to 30 MHz
–80 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB
Impedance
100
1, 120 1, 135 1, 150 1, 600 1
POTS dialer
DTMF
0 – 9, #, *
Phonebook
25 entries
Digital multimeter (DMM)
Test type
Snapshot and continuous
Impedance selection (for voltage measurement)
100 k
1, 1 M1, 10 M1
Notes
a. Subject to change without notice.
b. Typical, at 23 °C ± 3 °C, on batteries, with no USB connection.
c. Specifications based on 24 AWG (PE 0.5 mm) cabling.