Black shield shield shield black, Black, Outside sensor inside sensor 1 inside sensor 2 – Hired-Hand System 500 Power Curtain Controller Manual del usuario
Página 17: Open, Open close close out out, System-500 circuit board programación
System 500™ Power Curtain™ Controller
15
OUTSIDE SENSOR
CALIBRATION
DISPLAY CONTRAST
INSIDE SENSOR 2
CALIBRATION
INSIDE SENSOR 1
CALIBRATION
STAGE
PROGRAM
PROGRAM
BANK
VARIABLE SPEED FAN CONTROL
MINIMUM ADJUST
SPAN ADJUST
OFFSET ADJUST
Percent Max Speed
0
-
5
+
5
-
10
+
10
Degrees Fahrenheit
Degrees Fahrenheit
40
50
60
70
80
90
2
5
10
15
20
25
30
PLACE JUMPER ON PINS A AND B FOR STAGE ON STIR TIMER
C
B
A
STAGE 1
STAGE 2
STAGE 3
STAGE 4
STAGE 5
STAGE 6
STAGE 7
STAGE 8
INSTALL JUMPER FOR
5 MINUTE TIMER
PLACE JUMPER ON PINS B AND C FOR STAGE ON NEG. TIMER
PLACE JUMPER ON PINS A-B
FOR DUAL INSIDE SENSORS
PLACE JUMPER ON PINS B-C
FOR SINGLE INSIDE SENSOR
VAR. SPD.
AC
-
+
WHITE
BLACK
SHIELD
SHIELD
SHIELD
BLACK
WHITE
BLACK
WHITE
OUTSIDE SENSOR
INSIDE SENSOR 1
INSIDE SENSOR 2
CYCLE TIME ADJUST
RUN TIME ADJUST
2
5
3
4
Minutes
10
20
30
40
50
60
Seconds
3.5
2.5
4.5
CURTAIN CONTROL
PRIMARY CURTAIN
BLACK
WHITE
RED
WHITE
BLACK
SECONDARY CURTAIN
OPEN
OPEN
CLOSE
CLOSE
OUT
OUT
Sensor Switch
Sensor Switch
RED
System-500 Circuit Board
Programación
Localización de Conexiones
, Conectores, y
po
tenció
metros en el tablero de
Control del System 500.
Controles del
Ventilador Variable
Controles de la cortina
Calibración
VARIABLE SPEED FAN CONTROL
MINIMUM ADJUST
SPAN ADJUST
OFFSET ADJUST
Percent Max Speed
0
-
5
+
5
-
10
+
10
Degrees Fahrenheit
Degrees Fahrenheit
40
50
60
70
80
90
2
5
10
15
20
25
30
CYCLE TIME ADJUST
RUN TIME ADJUST
2
5
3
4
Minutes
10
20
30
40
50
60
Seconds
3.5
2.5
4.5
CURTAIN CONTROL
OUTSIDE SENSOR
CALIBRATION
DISPLAY CONTRAST
INSIDE SENSOR 2
CALIBRATION
INSIDE SENSOR 1
CALIBRATION
STAGE
PROGRAM
PROGRAM
BANK
AB
C
D
E
F
012 34
5
6
7
89
AB
C
D
E
F
012 34
5
6
7
89
VAR. SPD.
AC
-
+
WHITE
BLACK
SHIELD
SHIELD
SHIELD
BLACK
WHITE
BLACK
WHITE
OUTSIDE SENSOR
INSIDE SENSOR 1
INSIDE SENSOR 2
PRIMARY CURTAIN
BLACK
WHITE
RED
WHITE
BLACK
SECONDARY CURTAIN
OPEN
OPEN
CLOSE
CLOSE
OUT
OUT
Sensor Switch
Sensor Switch
RED
Conexiones de
Sensor/Ventilador Variable
Montaje de Reloj
Conexiones de
Máquina de Cortina
PLACE JUMPER ON PINS A AND B FOR STAGE ON STIR TIMER
C
B
A
STAGE 1
STAGE 2
STAGE 3
STAGE 4
STAGE 5
STAGE 6
STAGE 7
STAGE 8
INSTALL JUMPER FOR
5 MINUTE TIMER
PLACE JUMPER ON PINS B AND C FOR STAGE ON NEG. TIMER
PLACE JUMPER ON PINS A-B
FOR DUAL INSIDE SENSORS
PLACE JUMPER ON PINS B-C