3 medidas – VEGA WEIGHTRAC 31 Foundation Fieldbus Manual del usuario

Página 76

Advertising
background image

76

11 Anexo

WEIGHTRAC 31 • Foundation Fieldbus

42375-ES-131223

Priority

Description

User Error Codes

NE-107 Status

29

Software failure

80

FAILURE

28

Paramererization corrupt

72

FAILURE

27

Undefined 27

-

-

26

Undefined 26

-

-

25

Paramererization error

16, 17, 25, 52, 53, 57, 66, 117,

120

FAILURE

24

Conflict in MGC

121, 122, 141

FAILURE

23

Communication error in MGC

8

FAILURE

22

MGC slave reports error

38

FAILURE

21

Undefined 21

-

-

20

Undefined 20

-

-

19

Undefined 19

-

-

18

Detector temperature critical

125

OUT_OF_SPEC

17

Error while auto-standardization

73

FAILURE

16

Excessive radiation

123, 124

FAILURE

15

Input out of bounds

13

OUT_OF_SPEC

14

Error while signal processing

68

FAILURE

13

Undefined 13

-

-

12

Undefined 12

-

-

11

Undefined 11

-

-

10

Undefined 10

-

-

9

Undefined 9

-

-

8

Undefined 8

-

-

7

AITB simulated

29

FUNCTION_CHECK

6

Undefined 6

-

-

5

Undefined 5

-

-

4

Undefined 4

-

-

3

Undefined 3

-

-

2

Undefined 2

-

-

1

Error while trend recording

126, 127

GOOD

0

Reserved

-

Reserved

Not displayed

33, 45, 71, 86

-

11.3 Medidas

Los dibujos acotados siguientes representan solo una parte de las versiones posibles. Dibujos

acotados detallados se pueden descargar de www.vega.com/downloads y "Dibujos".