3 medidas, Carcasa plástica – VEGA VEGAPULS 67 (≥ 2.0.0 - ≥ 4.0.0) Foundation Fieldbus Manual del usuario
Página 77

77
11 Anexo
VEGAPULS 67 • Foundation Fieldbus
36534-ES-121113
FF desciptor
Description
Unit
ECHO_CURVE_PLICSCOM_
REQUEST
Parameters as curve selection and resolution
ECHO_CURVE_PLICSCOM_
LIMITS
Parameters as start and end
APPROVAL_WHG
Sensor acc. to WHG
DEVICE_STATE_CONFIG
Function check, maintenance required, out of specification
ELECTRONIC_TEMPERA-
TURE
Electronics temperature
RESET_PEAK_ELECTRO-
NIC_TEMP
FOCUS_RANGE_CONFIG
Width focusing range, time for opening the focusing range, min.
measurement reliability in and outside the focusing range
NOISE_DETECTION_INFO
Increase of the system noise
NOISE_DETECTION_CON-
FIG
System noise treatment
ECHO_MEM_SAVE_CUR-
VE_TYPE
ECHO_MEM_STATE
Busy, curve type, error code
11.3 Medidas
Los dibujos acotados siguientes representan solo una parte de las versiones posibles. Dibujos
acotados detallados se pueden descargar de www.vega.com/downloads y "Dibujos".
Carcasa plástica
~ 69 mm
(2.72")
ø 79 mm
(3.03")
112 mm (4.41"
)
M20x1,5/
½ NPT
~ 84 mm (3.31")
M16x1,5
112 mm (4.41"
)
M20x1,5/
½ NPT
1
2
ø 79 mm
(3.31")
Fig. 62: Variante de carcasa en tipo de protección IP 66/IP 68; (0,2 bar) con módulo de indicación y configuración
integrado aumenta la altura de la carcasa en 9 mm/0.35 in
1 Versión de una cámara
2 Versión de dos cámaras