Especificaciones técnicas, Copper specifications, Continued) – EXFO MaxTester 635 Manual del usuario

Página 184

Advertising
background image

Especificaciones técnicas

177

COPPER SPECIFICATIONS

a, b, c

(continued)

VF noise measurement

Frequency range

200 Hz to 20 kHz

Level range (dBm)

–90 to 20

Resolution (dB)

0.1

Uncertainty (accuracy)

–90 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to +20 dBm, uncertainty (accuracy) ±1 dB

Filters

ITU: none, psophometric, P-notched, 3.4 kHz, D-filter, 15 kHz
ANSI: none, C-message, C-notched, 3.4 kHz, D-filter, 15 kHz

Impedance

600

1

VF impulse noise

Low threshold (dBm)

–40 to 0, in 1 dB steps

Mid threshold

Low threshold plus separation

High threshold

Mid threshold plus separation

Separation (dB)

1 to 6, in 1 dB steps

Dead time (ms)

125

Filters

None, 3 kHz flat, C-message, psophometric,
notched and D filter (IEEE 743-1995)

Counter

Maximum 999 for each threshold

Timer

1 minute to 24 hours, default is 15 minutes

Power influence (noise to ground)

Noise range (dBm)

–60 to 10

Uncertainty (accuracy)

–60 dBm to –50 dBm ± 2 dB
–50 dBm to 10 dBm ± 1 dB

VF longitudinal balance

Frequency (Hz)

1004

Level range (dB)

0 to 100

Level uncertainty (accuracy) (dB)

±1

Impedance

600

1

Time-domain reflectometer (TDR)

Modes

Fully automatic operation with location of most significant event(s)

Distance range (m)

0 to 6700 (0 ft up to 22 000 ft)

Pulse width

15 ns to 20 μs

Test signals

Sine wave, compensated sine wave, half-sine wave and square wave

Amplitude

7.5 V p-p on cable, 9 V p-p open circuit

Velocity of propagation (VOP)

0.400 to 0.999

Distance uncertainty (accuracy)

d

(m)

±(0.5 m + 1 % x distance)

Units

Meters and feet

Load coil detection

Count

Up to 5

Plot (kHz)

Up to 10

Distance range (m)

Up to 8000 (up to 27 000 ft)

NOTES

a. Subject to change without notice.

b. Typical, at 23 °C ± 3 °C, on batteries, with no type B USB connection.

c. Specifications based on 24 AWG (PE 0.5 mm) cabling.

d. Qualified up to 300 m (1000 ft) and does not include the uncertainty due to VOP.

Advertising