A especificaciones técnicas, Mportante, Pruebas de cobre – EXFO FTB-610 Wideband Copper Test Module Manual del usuario

Página 343: Copper specifications

Advertising
background image

Pruebas de cobre

335

A Especificaciones técnicas

I

MPORTANTE

Las siguientes especificaciones técnicas pueden cambiar sin previo
aviso. La información contenida en esta sección se proporciona
únicamente como referencia. Si desea obtener las especificaciones
técnicas más recientes del producto, visite la página web de EXFO
en www.exfo.com

COPPER SPECIFICATIONS

a, b, c

Transmitter characteristics

Frequency range (200 Hz to 20 kHz)

Frequency resolution

1 Hz steps

Frequency uncertainty (accuracy)

±(50 ppm + 1 Hz)

Level range

–20 dBm to 0 dBm at 600

1

Level resolution

0.1 dB

Level uncertainty (accuracy)

±1 dB

Frequency range (20 kHz to 2.2 MHz)

Frequency resolution

1 kHz steps

Frequency uncertainty (accuracy)

±(50 ppm + 100 Hz)

Level range

–20 dBm to 0 dBm at 100

1

Level resolution

0.1 dB

Level uncertainty (accuracy)

±1 dB

Frequency range (2.2 MHz to 17 MHz)

Frequency resolution

1 kHz steps

Frequency uncertainty (accuracy)

±(50 ppm + 100 Hz)

Level range

–20 dBm to 0 dBm at 100

1

Level resolution

0.1 dB

Level uncertainty (accuracy)

±1 dB

Frequency range (17 MHz to 30 MHz)

Frequency resolution

1 kHz steps

Frequency uncertainty (accuracy)

±(50 ppm + 100 Hz)

Level range

–20 dBm to 0 dBm at 100

1

Level resolution

0.1 dB

Level uncertainty (accuracy)

±1 dB

Impedance

100

1, 120 1, 135 1, 150 1, 600 1

Receiver characteristics

Reception frequency range

200 Hz to 20 kHz
20 kHz to 30 MHz

Frequency uncertainty (accuracy)

±(50 ppm + 1 digit)

VF reception level range

–90 dBm to 15 dBm at 600

1

VF level uncertainty (accuracy)

200 Hz to 20 kHz
–90 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB

WB reception level range

–80 dBm to 15 dBm at 100

1, 120 1,135 1, 150 1

WB level uncertainty (accuracy)

20 kHz to 2.2 MHz
–80 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB

2.2 MHz to 30 MHz
–80 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB

Impedance

100

1, 120 1, 135 1, 150 1, 600 1

POTS dialer

DTMF

0 – 9, #, *

Phonebook

25 entries

Digital multimeter (DMM)

Test type

Snapshot and continuous

Impedance selection (for voltage measurement)

100 k

1, 1 M1, 10 M1

Notes

a. Subject to change without notice.

b. Typical, at 23 °C ± 3 °C, on batteries, with no USB connection.

c. Specifications based on 24 AWG (PE 0.5 mm) cabling.