External storage enclosure inventory, Network storage enclosure, Network storage enclosure status – HP Insight Control Manual del usuario

Página 70: Network storage enclosure inventory, Buses de host, Estado de los buses de host

Advertising
background image

Millisec/Transfer—Average time to complete a transfer to and from the selected external
storage enclosure

Enclosure Queue—Average number of transfer requests (reads and writes) waiting to be
serviced by the external channel storage enclosure

NOTA:

Insight Control Performance Management does not evaluate the performance of external

storage enclosures.

External Storage Enclosure Inventory

Enclosure Configuration—Type or model, name, and serial number of the external storage
enclosure.

Controller—Name and model of the enclosure and whether it is operating with redundant
controllers. If a redundant controller is configured, then both standby and active controllers
are listed (if redundancy is not configured, only active controllers are listed).

Host Bus Adapters (HBAs)—HBAs used to attach the enclosure to the server.

Windows/Linux Physical Disks—Logical volumes defined in the storage enclosure.

Network storage enclosure

The following information is provided for a network storage enclosure.

Network Storage Enclosure Status

Transfers/Sec—Average number of transfers (reads and writes) on this network storage
enclosure each second

MBytes/Sec—Average number of megabytes transferred on this network storage enclosure
each second

Millisec/Transfer—Average time to complete a transfer to and from the selected network
storage enclosure

Queue Length—Average number of transfer requests (reads and writes) waiting to be serviced
by the network storage enclosure

Network Storage Enclosure Inventory

Enclosure Configuration—Displays the type or model, name, and serial number of the network
storage enclosure.

Controllers—Displays the name and model of the enclosure and whether it is operating with
redundant controllers.

If a redundant controller is configured, then both standby and active controllers are listed.

If redundancy is not configured, only active controllers are listed.

Detected Servers—Displays a list of servers sharing the enclosure.

Buses de host

La siguiente información se proporciona para los buses de host.

Estado de los buses de host

Host Bus MBytes/Sec (MBytes de bus de host/segundo): El número medio de megabytes
transferidos a través de los buses de host cada segundo

70

Matriz de parámetros de medición