Mount the Telephone Entry System. If the unit is being used to provide access through an
automated vehicular gate, the unit must be mounted at least 10-feet away from the gate.
See pages 11-19.

1

2

Connect 16 VAC power to terminals 13-14. Connect a dedicated touch-tone loop-start
phone line to terminals 1-2. Connect ground wire to terminal 3.
See pages 25-26.

3

Program a MASTER CODE ( Section 3.1.1) - Factory Default is 9999

1. Open the cabinet and turn the Master Code switch ON.
2. Enter a four-digit Master Code on the keypad and then press *.
3. Turn the Master Code switch OFF.

4

Set the DIRECTORY CODE Length ( Section 3.2.1) - Factory Default is 3-digits

1. Press *20 and enter the Master Code.
2. Enter the desired Directory Code length (1-2-3 or 4) then press *.

5

Program Phone Numbers ( Section 3.2.2)

1. Press *01 and enter Master Code.
2. Enter a Directory Code then press *.
3. Enter a 7-digit Phone Number then press *.
4. Repeat 2-3 to enter more numbers.
5. Press 0# TOGETHER when finished.

QUICK START

6

Connect device(s) to be activated (gate operator, door strikes, etc.) to relay terminals as
required.