Set receive to transmit delay, Report number of floats, Report receive to transmit delay – VEGA VEGAPULS 67 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol Manual del usuario

Página 77: Código de error

Advertising
background image

77

11 Anexo

VEGAPULS 67 • Protocolo Modbus y Levelmaster

41369-ES-121113

Set Receive to Transmit Delay

Request:

Parámetro

Length

Code/Data

Set Receive to Transmit Delay

7 characters ASCII

UuuRmmm
mmm = milliseconds (50 bis 250),

default = 127 ms

Response:

Parámetro

Length

Code/Data

Set Receive to Transmit Delay

6 characters ASCII

UuuROK

Report Number of Floats

Request:

Parámetro

Length

Code/Data

Set Receive to Transmit Delay

4 characters ASCII

UuuF

Response:

Parámetro

Length

Code/Data

Set Receive to Transmit Delay

5 characters ASCII

UuuFn
n = number of measurement values

(0, 1 or 2)

Report Receive to Transmit Delay

Request:

Parámetro

Length

Code/Data

Report Receive to Transmit Delay

4 characters ASCII

UuuR

Response:

Parámetro

Length

Code/Data

Report Receive to Transmit Delay

7 characters ASCII

UuuRmmm
mmm = milliseconds (50 bis 250),

default = 127 ms

Código de error

Error Code

Name

EE-Error

Error While Storing Data in EEPROM

FR-Error

Erorr in Frame (to short, to long, wrong data)

LV-Error

Value out of limits