Communicaion settings – VIEWSONIC PJL9371 Manual del usuario

Página 72

Advertising
background image

PJL9371

ViewSonic

67

RS-232C Communication (continued)

Communicaion settings

1. Protocol

19200bps,8N1

2. Command format

("h" shows hexadecimal)

Byte Number

0





3

4

5

6

7

8

9 0  

Command

Action

Header

Data

Header

code

Packet

Data

size

CRC

flag

Action

Type

Setting

code

L

H

L

H

L

H

L

H

L

H

L

H

<SET>Change setting to

desired value [(cL)(cH)]

by [(eL)(eH)].

BEh EFh

03h 06h 00h

(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)

<GET>Read projector

internal setup value

[(bL)(bH)] .

(aL) (aH) 02h 00h (bL) (bH) 00h 00h

<INCREMENT>

Increment setup value

[(bL)(bH)] by 1.

(aL) (aH) 04h 00h (bL) (bH) 00h 00h

<DECREMENT>

Decrement setup value

[(bL)(bH)] by 1.

(aL) (aH) 05h 00h (bL) (bH) 00h 00h

<EXECUTE> Run a

command [(bL)(bH)].

(aL) (aH) 06h 00h (bL) (bH) 00h 00h

[Header code] [Packet] [Data size]

Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 ~ 4.

[CRC flag]

For byte number

5, 6,

refer to

RS-232C Communication command table

.

[Action]

Set functional code to byte number 7, 8.

<SET> = [01h, 00h], <GET> = [02h, 00h], <INCREMENT> = [04h, 00h]

<DECREMENT> = [05h, 00h], <EXECUTE> = [06h, 00h]

Refer to the Communication command table

.

[Type] [Setting code]

For byte number

9 ~ 

, refer to

RS-232C Communication command table

.

Advertising