Installation, Technical specifications – weld-pak 100 – Lincoln Electric WELD-PACK 100 PLUS IM546 User Manual
Page 9
Fuse or
Output Mode
Input Voltage
Breaker Size
Input Amps
Power Cord
Extension Cord
RATED
115V/60Hz
20 Amp
20
15 Amp, 125V,
Three Conductor
Three Prong Plug
#14 AWG
(NEMA Type 5-15P)
(2.1 mm
2
) or Larger
Up to 25 Ft. (7.6 mm)
CSA
115V/60Hz
15 Amp
12
15 Amp, 125V,
Three Conductor
Three Prong Plug
#12 AWG
(NEMA Type 5-15P)
(3.3 mm
2
) or Larger
Up to 50 Ft. (15.2 mm)
A-1
INSTALLATION
WELD-PAK 100
TECHNICAL SPECIFICATIONS – WELD-PAK 100
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
12.0 in
9.75 in
16.5 in
47 Ibs
305 mm
248 mm
419 mm
21.4 kg
PHYSICAL DIMENSIONS
Standard Voltage/Frequency
Input Current
115V/60Hz
20 Amps - Rated Output
115V/60Hz
15 Amps - CSA Rated output
Duty Cycle
Amps
Volts at Rated Amperes
20% Duty Cycle
88
18
20% Duty Cycle – CSA Rated Output
62
20
Welding Current Range (Continuous)
Maximum Open Circuit Voltage
Auxiliary Power
Rated DC Output: 0 - 88 amps
32
N/A
CSA Rated DC Output: 0 - 62 amps