Temperature reporting – Viper 5902 User Manual

Page 44

Advertising
background image

Feature Details

41

© 2009 Directed Electronics. All rights reserved.

before Advanced start can be activated.

Timer Mode operation
Activation begins a countdown timer as set in the

How Often? (Hours)

screen of the Adjustments menu (default 3 hours). When the timer
expires the engine starts and the

REMOTE START ACTIVATED

message is

sent to the remote control. When the Remote start runtime expires the
engine shuts off, the

REMOTE START DEACTIVATED

message is sent to the

remote control and the countdown timer restarts. This will repeat as
many times as set in the

How Many? (Starts)

screen of the Adjustments

menu (default 6 starts). Timer Start is exited after the final start.

Smart Start operation
Smart Start uses the “Hours” and “Starts” settings used in Timer Mode
in addition to temperature to automatically start the engine. Activation
begins the countdown timer. When the timer expires the vehicle inte-
rior temperature is checked and, if it exceeds the temperature thresh-
olds as set in the

Low Temp

and

High Temp

screens of the Adjustments

menu, the engine starts and the

REMOTE START ACTIVATED

message is

sent to the remote control. When the Remote start runtime expires the
engine shuts off, the

REMOTE START DEACTIVATED

message is sent to the

remote control and the countdown timer restarts. Smart Start is exited
after the final start.

Note

The vehicle battery voltage is also monitored and if below
10.5 volts the engine will start. The battery threshold can
be changed by an authorized Directed dealer if a higher or
lower threshold is desired.

Temperature Reporting

During Remote start the vehicle interior is checked regularly for tem-

Advertising