Other settings, Restoring the factory settings, Clearing the data (initialization) – Roland SP-555 User Manual

Page 50

Advertising
background image

50

Other settings

Here’s how to restore all settings of the SP-555, including the
sample and pattern data (banks A and B) and effect memory
settings to the factory-set state.

This operation will cause all internal memory data to be lost. If
necessary, you should make a backup before you proceed.
(

“Saving backup data (backup save)”

(p. 48))

1.

Switch off the SP-555’s power.

2.

Copy the “FCTRY” folder from the SP-555 UTILITY CD-
ROM into the “ROLAND” folder of a CompactFlash
card that was formatted by the SP-555.

The FCTRY folder of the SP-555 UTILITY CD-ROM contains the
factory preset data.

3.

Insert the CompactFlash card into the SP-555, and
while holding down [CANCEL], [REMAIN], and [DEL],
turn on the power.

The display will indicate “ini,” and [SAMPLING] will
blink.

If you decide to cancel the operation, simply turn off the
power.

4.

If you are sure you want to restore the SP-555 to the
factory settings, press [SAMPLING].

[SAMPLING] will light, and the dot in the display will
blink. When the blinking dot disappears, the operation
has been completed.

Never turn off the power while the dot is blinking. Doing so
may destroy the data.

Here’s how to erase all of the internal memory (bank A and
B) sample and pattern data, as well as the effect memory
settings, and initialize other internal settings to the default
state.

This operation will cause all internal memory data to be lost. If
necessary, you should make a backup before you proceed.
(

“Saving backup data (backup save)”

(p. 48))

1.

While holding down [CANCEL], turn on the power of
the SP-555; this will turn off the internal memory
protect setting.

The display will indicate “P.oF,” indicating that
protection has been disabled for the samples and pads
of banks A–J.

2.

Switch off the SP-555’s power.

3.

While holding down [CANCEL], [REMAIN], and [DEL],
turn on the power.

The display will indicate “ini,” and [SAMPLING] will
blink.

If you decide to cancel the operation, simply turn off the
power.

4.

If you are sure you want to initialize the SP-555, press
[SAMPLING].

[SAMPLING] will light, and the dot in the display will
blink. When the blinking dot disappears, the operation
has been completed.

Never turn off the power while the dot is blinking. Doing so
may destroy the data.

Restoring the factory settings

Clearing the data (initialization)

SP-555_e.book 50 ページ 2007年6月25日 月曜日 午前9時9分

Advertising