4 radar set up parameters, Ebl display – Raymarine Radar equipment Raychart Chartplotter RC530 PLUS User Manual

Page 169

Advertising
background image

Chapter 7: Setting Up the System Defaults

7-11

R

adar S

et U

p

Pa

ra

m

ete

rs

7.4 Radar Set Up Parameters

The RADAR SET UP option allows you to set up the radar according to your
system configuration and your personal preferences.

Note: Some parameters can only be changed if you are using the Master dis-
play (that is, the display to which the scanner is connected).

The following table lists the Radar Set Up parameters and their options,
shows the factory default setting, and provides a space for you to make a
note of your new default setting. Each parameter is described in the fol-
lowing subsections.

EBL Display

The mode of the bearing data displayed for Electronic Bearing Lines
(EBLs). The bearing information can be displayed in either of two forms:

Relative: The bearing relative to your vessel’s heading.

Mag/True: The actual bearing in either degrees magnetic or degrees true.
This option is only available if you are obtaining data from a compass.

If you choose this mode, the selection you made for Bearing Mode
determines whether °M or °T is displayed in the EBL data boxes. The
current units are shown for the heading value in the status bar at the top
of the screen.

Table 7-2:

Radar Set Up Parameters

Parameter

Options

Factory Default

New Default

EBL DISPLAY

MAG/TRUE, RELATIVE

RELATIVE

TIMED
TRANSMIT

OFF, ON

OFF

TRANSMIT PERIOD

10 scans, 20 scans, 30 scans

20 scans

STANDBY PERIOD

3, 5, 10 or 15 mins

10 minutes

DEFAULT MARK
SYMBOL

, , ,

MARK DISPLAY

OFF, ON

ON

CLEAR MARKS

Press soft key to clear marks
database

N/A

CUSTOM SCALE

OFF, ON,SET RANGES...

OFF

BEARING
ALIGNMENT

Slider value

ANTENNA SIZE

4 ft., 6ft (only if an open array
scanner is connected)

4 ft.

SEND ON HSB

ON, OFF

ON