Panasonic PC8 User Manual

Page 4

Advertising
background image

Panasonic Protocol Converter Manual V10.2 5Mar 09

Page 4/16

Technical Specification

Power Requirements

9Vdc 500mA


Input

2 or 4 wire RS485 (switch selectable, SW3/8)

Panasonic

RS485

9600,N,8,1

or

19200,N,8,1


Outputs

8 * RS485, either 2 or 4 wire
Maximum cable run approx 4000 Feet/1200m


Facilities

LED as power and data indication


Other Outputs

RS232 monitor output via chassis mounted DB9 connector.


Boxed Dimensions

19” 1U rack 100mm deep rack mountable case.


Version History

V10.2 5 Mar 2009

Update to show new 00007-6 PCB format.

V10.1 6 Sept 2007

Addition of notes concerning Vicon dome integration and SX650 matrix firmware.

V10 17 August 2007

Added support for Vicon dome protocol at 4800 or 9600 baud

V9 11 May 2007

Added Wash/Wipe support for Pelco protocol

V8 14 July 2006

Added support for Dennard dome protocol at 9600 baud

V7 8 Sept 2005

Added support for Pelco P at 2400, 4800 or 9600 baud

V2 5 March 2004

Improved control, LED status improved, added support for patrol and path

V1 26 Mar 2003

VCL TP protocol (9600,N,8,1)

Advertising