Troubleshooting – Lincoln Electric INVERTEC V350-PRO IM708 User Manual

Page 24

Advertising
background image

E-4

TROUBLESHOOTING

E-4

V350-PRO (CE)

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Fault Codes

Code Description

Corrective Action

31

Primary over current.

If condition persists

The machine needs to

contact an authorized

be turned off and back

Lincoln Field Service

on to reset the machine.

Shop

32

CAP bank A under voltage.

Check input power

Self-clearing as

33

CAP bank B under voltage.

reconnect to make sure

condition ceases.

34

CAP bank A over voltage.

the machine

35

CAP bank B over voltage.

is connected for the input

37

Soft start Failed.

power being supplied.

Cycle power.

39

Glitch on the primary over

Check the machine

Self-clearing as

current fault interrupt; possibly

ground.

condition ceases.

caused by noise or a signal level

If problem persists

(misc. hardware fault #1)

contact an authorized
Lincoln Field Service
Shop

43

CAP delta; CAP A and B are out

Check input power

of balance.

reconnect to make sure
the machine is
connected for the input
power being supplied.

44

Main CPU problem. The DSP

Check the machine

has detected a problem with the

ground.

CPU.

47

Glitch on the CAP/heart beat

If problem persists

interrupt; possibly caused by

contact an authorized

noise or a signal level right at

Lincoln Field Service

the trip threshold.

Shop

(misc. hardware fault #2)

48

The main contactor opened

If condition persist

Self-clearing

unexpectedly. (misc. hardware

contact an authorized

fault #3)

Lincoln Field Service
Shop

"bad The selected weld mode does

If condition persists

Press the Mode

node’ not exist in the weld table that is

contact an authorized

Select button to

####” presently loaded in the machine.

Lincoln Field Service

select a different

Shop

mode

Advertising