E-3

TROUBLESHOOTING

E-3

V350-PRO (CE)

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Thermal symbol is lit

Wire feeder won’t work. Apparently
no power to wire feeder

1. Check for proper fan operation
2. Check for material blocking

intake or exhaust louvers.

1. Check circuit breakers by the

wire feeder receptacles on the
rear of the machine. Reset

2. Check to make sure the wire

feeder is connected to the correct
wire feeder receptacle. (115VAC
or 24/42VAC)

3. Check the control cable between

the power source and the wire
feeder for continuity.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.