A-3

INSTALLATION

A-3

V350-PRO (CE)

LN-10 Connection Instructions

Turn the Invertec power switch "off".

Connect the K1505 control cable from the LN-10 to

the Invertec 24/42VAC 14-pin amphenol connector
on the rear of the Invertec.

Connect the electrode cable to the output terminal

of polarity required by the electrode. Connect the
work lead to the other terminal.

Set the meter polarity switch on the front of the

Invertec to coincide with wire feeder polarity used.

See the LN-10 manual for details on accessing

Control DIP Switch

LN-742 Connection Instructions

Turn the Invertec power switch "off"

Either a K591 or a K593 Input cable assembly is

required to connect the LN-742 to the Invertec.

Connect the control cable from the LN-742 to the

24/42 VAC 14-pin wire feeder amphenol on the rear
of the Invertec.

Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect the
work lead to the other terminal.

Set the meter polarity switch on the front of the

Invertec to coincide with wire feeder polarity used.
The wire feeder will now display the welding volt-
age.

If a remote control such as K857 is to be used with

the LN-742, the remote can be connected directly to
the 6pin amphenol on the front of the Invertec or use
a K864 adapter to connect the LN-742 and the
remote to the 24/42VAC 14-pin wire feeder amphe-
nol connector on the rear of the Invertec.

Cobramatic Connection Instructions

Turn the Invertec power switch "off"

Connect the control cable from the Cobramatic to

the 24/42 VAC 14-pin wire feeder amphenol on the
rear of the Invertec.

Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect the
work lead to the other terminal.

Set the meter polarity switch on the front of the

Invertec to coincide with wire feeder polarity used.

If a remote control such as K857 is to be used with

the Cobramatic, the remote can be connected
directly to the 6pin amphenol on the front of the
Invertec or use a K864 adapter to connect the
cobramatic and the remote to the 24/42VAC 14-pin
wire feeder amphenol connector on the rear of the
Invertec.

TIG MODULE K930-2
The TIG Module connects to the

CE

version with a

K936-1 (9-14 pin) control cable. Connect the K936-1
to the 115VAC Wire Feeder Amphenol on the rear of
the V350-PRO (CE).

CONNECTION OF WIRE FEEDERS TO V350-PRO (CE)
Wire feeders other than LN-7, LN-10 and LN-25 may
be used provided that the auxiliary power supply
capacity of the Invertec is not exceeded. K867
Universal Adapter Plug may be required. See con-
nection diagram S24985 on page F-4.

REMOTE CONTROL OF INVERTEC
Remote Control K857, Hand Amptrol K963 and Foot
Amptrol K870.

UNDERCARRIAGE MOUNTINGS

5.50

10.00

MOUNTING HOLE LOCATIONS

M19527

1/4-20 NUT (4 PLACES)

NOTE: MOUNTING SCREWS CA

8/00

N NOT PROTRUDE MORE THAN

0.5 INCHES INSIDE THE MACHINE.

11.84