HELIX DN9340E/DN9344E Remote Control Software

User Guide


21 of 65

At the Filter Mode tab

Use the Unit Display drop down menu to set the display mode that DN9340 units should
assume when taken out of slave operation; this only comes into effect if the slave is a

DN9430. The choice made here has no effect on your AddIn device display.

To Bypass all the Filters on the current channel

Tick the †Bypass check box in the Filter Mode tab by clicking on it.

To add a Filter to the graph

1

Click on the Add button in the Filter Shaping tab. A notch filter, with target, appears on the
left-hand edge of the graph (20Hz) with the target and a filter

panel added to the tab.

2

Select a Filter Type from the associated drop down menu on the
Shaping tab. The control panel fields change accordingly and
the filter (with target) resets to a suitable default freq., for

example, if you select LPF the filter resets to 20kHz. To obtain

a peaking High or Low Pass filter, select LPF or HPF then select

a Peak from the Type drop down menu (right).

3

Left click on the target and drag it horizontally to the required

frequency or type in a value using a k suffix for frequencies of

1kHz and above.

4

Set the remaining fields, for example, Level and Slope for a hi-
shelf filter. Levels can be coarsely adjusted by dragging the target up or down. Notch filter

Q values can be adjusted by right clicking and dragging the mouse up or down.

5

If required, fine tune the settings at the PEQ panel by scrolling the Frequency, Level and Q
fields.

To move the target onto a different filter

Click on the control panel of the required filter. The selected panel becomes highlighted
and the target cursor moves to the filter.

To switch a Filter out of the circuit

1

Tick the † Out check box at the top right-hand corner of
the Filter’s control panel.

The Filter is faded to grey on the graph and its contribution is

removed from the overall frequency response. The target
remains active so that it can still be adjusted while switched

out.

2

To switch the Filter in again, clear the check box.

HPF and LPF
Peaks are set in

the Type field.

Switching a

filter out