Klark Teknik DN9344E User Manual

Page 45

Advertising
background image

HELIX DN9340E/DN9344E Remote Control Software

User Guide


45 of 65

To take the entire network offline

1

Switch to the FastNav

®

screen by clicking on the red Fast Nav. button in any AddIn or by

maximising the DN9340 Navigation icon on the Windows Start bar.

2

Choose All Units Offline.

The buttons on the FastNav

®

screen and individual Device screens are toggled accordingly.

7.6.3 Activity

Indicators

During online operation, the Activity Indicators of the HELIX AddIn provide audio metering for the

respective unit. These mirror the Activity Indicators of the Unit (for further information on metering,

refer to the DN9340E/DN 9344E Operator Manual).

7.6.4 Bypassing

Channels

Using HELIX RCS as the Master enables Channels, EQ types or EQ sections/filters to be quickly switched

in an out, as follows:

To Bypass…

From the FastNav

®

screen …

A channel

1 Select the Home view of the channel.

2 Tick

the

†

Bypass box in the highlighted panel of the lower tab (that

is, the active channel).

A EQ type

1 Locate the required channel Navigation Strip and click on the

required EQ view button.

2 Tick the † Bypass box in the upper mode tab.

EQ section

1 Locate the required channel Navigation Strip and click on the

required EQ view button.

2 Tick the † Out check box for the respect EQ section/filter in the lower

tab.

7.6.5 Troubleshooting

If you are having difficulty setting units online, using either the

Go Online

button (on device workspace)

for a single unit or the All Units Online global button (on FastNav

®

) for all the units, try reloading the .ktg

file. If required, save the file first.

If this does not solve the problem, try restarting Elgar.

Advertising
This manual is related to the following products: