Electromagnetic Compatibility

Release 11/02

4–2

SIMATIC Panel PC 670/870 Start-Up Instructions

Sinusoidal wave interference

RF Radiation complying with EN 61000-4-3

Electromagnetic RF field, amplitude-modulated
from 80–1000 MHz
10 V/m
80 % AM (1 kHz)

Electromagnetic RF field, pulse-modulated
900

±

5 MHz

10 V/m
50 % ED
200 Hz pulse repetition frequency

RF interference on signal lines, data lines, etc. complying with EN 61000-4-6,
radio frequency, asymmetric, amplitude-modulated
from 0.15 –80 MHz
10 V RMS value
80 % AM (1 kHz)

Interference emission

Radiated interference of electromagnetic fields according to
EN 55011: Limit Value Class A, Group 1.

from 30–230 MHz

< 30 dB (µV/m)Q

from 230–1000 MHz

< 37 dB (µV/m)Q

measured from a 30 m distance

Radiated interference from mains AC line power supply complying with EN 55011:
Limit Value Class A, Group 1 (only 230 V operating units)

from 0.15–0.5 MHz

< 79 dB (µV)Q
< 66 dB (µV)A

from 0.5–5 MHz

< 73 dB (µV)Q
< 60 dB (µV)A

from 5–30 MHz

< 73 dB (µV)Q
< 60 dB (µV)A