Unpacking and Installing the Panel PC 670/870

Release 11/02

1–12

SIMATIC Panel PC 670/870 Start-Up Instructions

Additional permissible installation position for the computer unit complying
with UL508/CSA 22.2 No. 142

An installation angle of

±

15° is permitted in this position.

Position 5 (interfaces at bottom)

Figure 1–10

Additionally permissible installation positions for the computer unit in a
decentralized design

Select an appropriate installation location taking the installation notes and selected
installation angle into account.

Note

Ensure sufficient air volume for heat transportation within the switching
cabinet/panel. Further information on this is available in the Panel PC 670/870
Operating Unit Equipment Manual, Chapter 2.4.
Also ensure sufficient free space to pull out the Panel PC 670/870 from the
installation cut-out.

When selecting the installation location, ensure that the switching cabinet/panel
contains reinforcement bars to stabilize the cut-out. If necessary, install such
reinforcement bars.

Figure 1–11 below contains the dimensioning for the holes for the screw
mountings.